BMPDN - 1065/5018/5028/5034/5046/5065 DEVELOPER, 5R
- MSDS: BMPDN
- Manufacturer: XEROX CORP
- Product Name: 1065/5018/5028/5034/5046/5065 DEVELOPER, 5R
- National Stock Number: 6850-00N025113
Product Identification
Product ID:1065/5018/5028/5034/5046/5065 DEVELOPER, 5R
MSDS Date:05/25/1990
FSC:6850
NIIN:00N025113
MSDS Number: BMPDN
Responsible Party
ROCHESTER, NY 14644
US
Emergency Phone: 716-422-2177
Info Phone: 800-828-6571
Cage: 0E6G9
Contractor
Telephone: 800-828-6571/716-422-2177
Cage: 26921
Ingredients
CARRIER (CONSISTING OF INGREDIENTS 2 & 3)
RTECS: 9999999ZZ
Fraction By Weight: >95%
IRON;(STEEL POWDER)
CAS: 7439-89-6
RTECS: NO4565500
Fraction By Weight: >99%
OSHA PEL 10 MG/M3 DUST
ACGIH TLV: 5 MG/M3 FUME
FLUOROPOLYMER
CAS: 24937-97-1
Fraction By Weight: <1%
TONER (CONSISTING OF INGREDIENTS 5 & 6)
RTECS: 9999999ZZ
Fraction By Weight: <5%
STYRENE POLYMER WITH 1,3-BUTADIENE;(STYRENE/BUTADIENE
CAS: 9003-55-8
RTECS: WL6478000
Fraction By Weight: 75-80%
IRON OXIDE
CAS: 1332-37-2
RTECS: NO7380000
Fraction By Weight: 15-20%
OSHA PEL 10 MG/M3 DUST
ACGIH TLV: 5 MG/M3 FUME
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MINIMAL RESPIRATORY TRACT IRRITATION
MAY OCCUR AS WITH EXPOSURE TO LARGE AMOUNTS OF ANY NON-TOXIC DUST.
IN A XEROX SPONSORED CHRONIC INHALATION STUDY IN RATS USING A
SPECIAL TEST TONER, THERE WERE NO LUNG CHANGES AT ALL IN LOWEST
EXPOS LEVEL (1 MG/M3), MOST RELEVANT LEVEL TO POTNTL HUMAN EXPOS.
VERY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:SLIGHT DEGREE OF FIBROSIS WAS NOTED IN
25% OF ANIMALS AT MIDDLE EXPOS LEVEL (4 MG/M3) WHILE A SLIGHT
DEGREE OF FIBROSIS WAS OBSERVED AT HIGHEST EXPOS LEVEL (16 MG/M3)
IN ALL ANIMALS. THESE FI NDINGS ARE ATTRIBUTED TO "LUNG
OVERLOADING" A GENERIC RESPONSE TO EXCESSIVE AMTS OF ANY DUST
RETAINED IN LUNGS(SUPDAT)
Medical Cond Aggravated by Exposure:NONE WHEN USED AS DESCRIBED BY
PRODUCT LITERATURE.
First Aid
First Aid:EYE:FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SKIN:WASH WITH
SOAP & WATER. INHAL:REMOVE FROM EXPOSURE. INGEST: DILUTE STOMACH
CONTENTS WITH SEVERAL GLASSES OF WATER.
Fire Fighting
Extinguishing Media:WATER, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:IF SPILLED, SWEEP UP OR VACUUM.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE.
Other Precautions:AVOID PROLONGED INHALATION OF EXCESSIVE DUST.
Exposure Controls
Respiratory Protection:NONE REQUIRED WHEN USED AS INTENDED IN XEROX
EQUIPMENT. NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:NONE REQUIRED.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP:FOR A PROLONGED INTERVAL. THE SPECIAL TEST TONER WAS
TEN TIMES MORE RESPIRABLE THAN COMMERCIALLY AVAILABLE XEROX TONER
TO COMPLY WITH EPA TESTING PROTOCOL AND WOULD NOT FUNCTION PROPER
LY IN XEROX EQUIPMENT.
Chemical Properties
HCC:N1
Spec Gravity:5
Appearance and Odor:BLACK GRANULAR/FAINT ODOR
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:PRODUCTS OF COMBUSTION MAY BE TOXIC.
AVOID BREATHING OF SMOKE.
Disposal
Waste Disposal Methods:NO SPECIFIC WASTE DISPOSAL METHOD REQUIRED.
DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.